Waste Gas Treatment System for Pharmaceutical Chemical Plant |
|
industry involved |
Pharmaceutical Chemical Plant |
Pollution characteristics |
Nitrogen Oxides (NO, NO₂) |
gas concentration |
215 kg/h |
air volume |
3000m³/h |
Air pollution control system |
Six-stage high-tower water scrubbing absorption → Three-stage alkaline scrubbing |
purification efficiency |
99.50% |
Technical References:
-
The multi-stage scrubbing process aligns with pharmaceutical industry standards for inorganic gas treatment, particularly for nitrogen oxide removal .
-
High-tower water scrubbing is widely adopted in chemical exhaust treatment, offering enhanced gas-liquid contact efficiency compared to conventional scrubbers .
-
Three-stage alkaline scrubbing ensures pH stability during NOx neutralization, critical for maintaining ≥99% removal efficiency in continuous operations .
Compliance Documentation:
-
This design meets the emission limits specified in:
-
Emission Standard of Air Pollutants for Pharmaceutical Industry (GB 37823-2019)
-
Technical Specification for Exhaust Gas Treatment in Chemical Industry (HJ 2028-2013)
-